• Type B Residual Current Breaker 2p 25A Meets to IEC/En62423
  • Type B Residual Current Breaker 2p 25A Meets to IEC/En62423

Type B Residual Current Breaker 2p 25A Meets to IEC/En62423

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Air
Installation: DIN Rail
Structure: MCB
Samples:
US$ 50/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Poles Number
4p
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000, CE, CB, SGS
Transport Package
Carton
Specification
20 pcs per carton
Trademark
RAVELO
Origin
China
HS Code
8536200000

Product Description

Description:
· Type B RCCB is the secret that makes Electric Vehicle Charging Point much safer than traditional charging point. It is a multiple purpose safety device that manage all potential residual current, and protect users from potential electric shock.
· AC residual current.
· Pulsating DC residual current.
· Sinusoidal half-wave current superposes 6mA smooth DC residual current.
· Multifrequency recombination residual current.
· Less than 1000Hz AC residual current.
· AC current superimposes 10mA or 0.4In smooth DC residual current.
· Sinusoidal half-wave current superposes 10mA or 0.4In smooth DC residual current.
· DC residual current generated by a Single-phase rectifier circuit.
· DC residual current produced by three-phase rectifier circuit.
· Smooth DC residual current.
· Control electric circuits.
· Protect people against indirect contacts and additional protection against direct contacts.
· Protect installations against fire hazard due to insulation faults.
· Residual current circuit breakers are used in housing, tertiary sector and industry.


Detectable wave form:
· Type B
Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.
· Tripping sensitivity
30mA - additional protection against direct contact.
100mA - co-ordinated with the earth system according to the formula IΔn<50/R, to provide protection against indirect contacts.
300mA - protection against indirect contacts, as well as fire hazard.
· Tripping time
Instantaneous
It ensures instantaneous tripping (without time-delay).


Technical specification:
Standard IEC/EN 62423 AS/NZS 61008-1
Type (wave form of the earth leakage sensed) B
Number of Pole 1P+N, 3P+N
Rated voltage Ue 1P+N 240v~, 3P+N 415v~
Rated Current 25A, 32A, 40A, 63A
Insulation Voltage 500V
Short-circuit Current 500(In=25A/40A)
Rated residual making 630(In=63A)
Short-circuit current Inc=IΔc 10,000A
Rated Residual Operating Current 30, 100, 300mA
Break time under IΔn ≤0.1s
Rated frequency 50Hz
Rated Impulse Withstand Voltage(1.2/50)Uimp 4,000V
Dielectric Test Voltage at ind. Freq. For 1 min 2.5kV
Pollution degree 2
Mechanical Life 10,000 cycles
Electrical Life 4,000 cycles
IP Rating 20
Fault Current Indicator Yes
Ambient Temperature (with-daily average ≤ 35ºC ) -25...+40ºC
Storage temperation -25...+70ºC

Outline dimension (mm):
Type B Residual Current Breaker 2p 25A Meets to IEC/En62423

Type B Residual Current Breaker 2p 25A Meets to IEC/En62423
Type B Residual Current Breaker 2p 25A Meets to IEC/En62423
Type B Residual Current Breaker 2p 25A Meets to IEC/En62423


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees